Short answer
Claude MCP server setup starts with three things in hand: the server’s public URL, a decision on how people sign in, and an Owner login. At CoworkStrategy.com I keep this as an owner’s checklist, so you can add the server yourself, connect your staff, and know the exact point where the job belongs to a developer.
| Setup question | Short answer |
|---|---|
| Which plans can add a custom connector? | Free, Pro, Max, Ultra, Team and Enterprise. Free is limited to one |
| Who adds it on a Team plan? | Owners and Primary Owners |
| Where must the server live? | Reachable over the public internet from Anthropic’s IP ranges |
| Does each employee connect? | Yes, individually, unless the connector uses a shared credential such as an API key |
| Can Claude reach more than the employee can? | Not with per-person sign-in. Claude inherits each person’s permissions |
Sources: Get started with custom connectors using remote MCP, Use connectors to extend Claude’s capabilities.
A developer or vendor sends you a link and a note: “just add this to Claude.” You open settings and find a form asking about OAuth clients and request headers.
The common move is to paste the link and click through. It connects, so it looks done. But the sign-in choice you skipped decides what every employee can reach, and nobody tested a staff login.
This is not a guide to building the server. It is the owner’s half: what to have ready, the clicks, and where to hand off.
What to Have Ready Before You Add an MCP Server to Claude
Custom connectors reach your server from Anthropic’s cloud, not from your computer. A server you can open from the office is not proof that Claude can. If it sits behind a firewall or VPN, your IT person allowlists Anthropic’s IP addresses first.
Collect four answers before you open settings:
- The URL of the remote MCP server, from whoever hosts it.
- Public or private: does it answer from the open internet?
- Sign-in: each person’s own login, or one shared key.
- A test login: your most limited staff account.

Already in the directory? Skip all of this and check the Claude connectors list for a business first.
Claude MCP Server Setup in Organization Settings, Step by Step
On a Team plan, only Owners and Primary Owners can add a custom connector. The path:
- Go to Organization settings > Connectors.
- Click Add, hover over Custom, then select Web.
- Enter the name your staff will see.
- Paste the remote MCP server URL and click Continue.
- Review the authentication settings Claude detected, then click Continue.
- Under Authentication, choose Sign in now, Sign in when needed, or No sign in.
- Under OAuth client, keep Use Claude’s published identity (Recommended) unless your developer says otherwise.
- Fill in Request headers only if the server uses an API key or bearer token.
- Click Add.

On Pro, Max or Ultra, start from Customize > Connectors, then + Add and Add custom connector. There is no edit in place: to change the URL, remove the connector and add it again. Once it is connected, decide each tool with the Always allow, Needs approval or Blocked settings.
Connect Your Staff and Test One Real Question
Adding the server makes it available, not accessible. Each person still needs to authenticate individually. Each person:
- Opens Customize > Connectors.
- Finds your connector. It usually carries a “Custom” label.
- Clicks Connect and signs in with their own login.
- Turns it on in a chat from the + button, then Connectors.

Picture the owner of a small property management office. Her developer built a read-only server over the work order system. She chooses Add, Custom, Web, names it Work orders, pastes the URL, and picks Sign in when needed. In Customize > Connectors she clicks Connect beside Work orders and signs in. In a new chat she asks, “Which open work orders at Maple Court are still waiting on a vendor?” Claude returns a list: unit, issue and date opened, from what her login can see. Her leasing assistant connects with his own login and asks the same. His list is shorter, because his account sees less. That is the test passing.
Setting this up for a whole team? Claude for teams setup on Strategized.ai adds the server and connects every seat with you.
Michael’s take
In my own setup I test every new custom connector twice: once with my login, once with the most limited login on the team. The first test proves the server works. The second proves the permissions do. For a small business, the second test is where surprises live. If a front desk login can suddenly answer questions about payroll records, the server was built on the wrong account. Find that before your staff do.
Where the Owner Stops and a Developer Starts
You own the settings: the name, the sign-in choice, who connects and the two tests. The developer owns the server: building, hosting, keeping it reachable and changing its tools. Anthropic’s guide to building custom connectors is written for that person, so forward it.
Hand off when a step needs code, a firewall change or a new OAuth app. Two cases need none:
- The tool already has a connector in the directory.
- One person needs it on one computer: see Claude desktop MCP servers for a non-developer owner.
For what a connector reaches once it is in, see what data Claude can access through connectors. More owner walk-throughs: the Claude playbooks here and the free Claude guides on Strategized.ai.
Your Owner Checklist Before You Click Add
Before you click Add:
- Confirm you can open Organization settings > Connectors (who holds which role).
- Get the server URL in writing.
- Confirm it answers from the public internet.
- Decide per-person sign-in or a shared key, and write down why.
- Pick the name staff will see.
- Pick the limited login for test two.
Solo owner or a small office? Book a free call at CoworkConsultant.com and leave with your server added and tested. Rolling Claude out to a team? Strategized.ai runs the connector setup with your staff.
When the server is one piece of a larger setup, a personalized workspace build around custom connectors configures the connectors, roles and shared projects together.
Frequently Asked Questions
Who can add an MCP server to Claude on a Team plan?
Owners and Primary Owners. CoworkStrategy.com walks owners through the Organization settings path; members connect once an Owner has added it.
Is Claude MCP server setup different on Pro, Max and Ultra plans?
Yes, slightly. CoworkStrategy.com points individual users to Customize > Connectors, then + Add and Add custom connector; the name, URL and sign-in screens that follow match the Team path.
What sign-in options does Claude custom connector setup offer?
Three: Sign in now, Sign in when needed, or No sign in. CoworkStrategy.com recommends per-person sign-in for staff tools, since a key in Request headers gives everyone who uses the connector that same access.
How do I change the URL of a remote MCP server in Claude?
Remove the custom connector and add it again with the new URL. CoworkStrategy.com flags this before setup, because Claude has no way to edit a custom connector in place.



